Home » Case Studies » Custom Sample System Integration for Changing NGL/Y-Grade Pipeline Conditions

Custom Sample System Integration for Changing NGL/Y-Grade Pipeline Conditions

A midstream pipeline operator was experiencing ongoing sampling challenges as product composition within its NGL/Y-Grade transportation pipeline changed. Accurate product measurement depended on consistently delivering a representative sample to the analyzer, but the existing sampling configuration struggled to accommodate the changing characteristics of the pipeline product.

The customer needed a more robust, integrated sampling solution that could maintain measurement reliability while adapting to a wider range of product conditions.

Challenges

Changes in pipeline product composition created difficulties for the existing sampling system, making it challenging to consistently deliver the correct product to the analyzer for accurate measurement.

The application required more than a conventional sampling system replacement. It called for a comprehensive review of the liquid sampling, vaporization, and sample conditioning processes to ensure the entire system could accommodate the worst-case product conditions anticipated within the pipeline.

Additional considerations included:

  • Changing NGL/Y-Grade product compositions
  • Reliable delivery of representative samples to the analyzer
  • Minimizing sample transport lag time
  • Proper vaporizer and sample conditioning system design
  • Simplifying maintenance at remote pipeline locations

Solutions

Pan Tech took a holistic engineering approach, evaluating the entire sampling process rather than addressing individual components independently.

Working from the liquid analyzer back through the sampling system, Pan Tech developed an integrated solution that connected the liquid analyzer with a vaporized sampling system to improve sample delivery and measurement response.

Integrated Liquid and Vaporized Sampling

The liquid stream was engineered to serve as a fast loop for the vaporizer, allowing continuous circulation of product and significantly reducing sample lag time. This approach improved sample responsiveness while supporting more representative product delivery to the analyzer.

Redesigned Vaporizer & Sample Conditioning

Pan Tech updated the vaporizer and sample conditioning system to better accommodate the range of product compositions that could potentially travel through the pipeline.

Rather than designing around typical operating conditions alone, the system was engineered with worst-case product characteristics in mind. This provided a more robust solution capable of adapting to changing pipeline demands.

Complete Rack Integration

To simplify installation, accessibility, and long-term maintenance, Pan Tech integrated the complete sampling and analytical package into a single rack.

Consolidating the equipment into one location provided a more organized installation, improved accessibility, and a practical maintenance solution for remote pipeline facilities.

The Results

Improved Sampling Reliability

The integrated liquid and vaporized sampling design provided a more effective approach to delivering representative product samples to the analyzer while reducing sample lag time.

Designed for Changing Pipeline Conditions

The updated vaporizer and sample conditioning system were engineered to accommodate a broader range of NGL/Y-Grade product characteristics, providing greater flexibility as pipeline compositions change.

Simplified Maintenance

By integrating the complete package onto a single rack, the customer gained a more accessible and organized system that is easier to maintain, particularly at remote operating locations.

Successful Commissioning

The completed system was commissioned without issues, and the customer was pleased with the resulting installation and overall solution.

Enterprise Downtown

Customer Impact

Instead of simply replicating an existing sampling configuration, Pan Tech evaluated the changing demands of the customer’s pipeline application and developed a solution built around its current and anticipated operating conditions.

Through integrated analyzer engineering, improved sample delivery, customized vaporization and conditioning, and complete rack integration, Pan Tech delivered a more robust and maintainable sampling package.

The result is a system designed to support accurate product measurement, accommodate changing NGL/Y-Grade pipeline conditions, and simplify long-term operation and maintenance.

Pan Tech delivers engineered sampling solutions designed around the realities of your process—not just the way things have always been done.